Tumble Dryer

My Hoover VHV680C-80 tumble dryer is not heating, element and temp. sensor tested and ok. what can it be?

February 14, 2017

Customer Question

My Hoover VHV680C-80 tumble dryer is not heating. I've tested the temperature sensor and the heating element and both seem fine. After viewing your videos I'm suspecting the problem can be the relay on the printed circuit board.I have attached 3 pics. One of the whole board. One of the relay for info,and one with my thumb in to show there are 5 pins.Relay info. Omron G5LA-1-HA, 12vdc, 10a 277ac, 10a 250 ac. can you help me identify the right relay for my dryer pcb

P

Paul Says:

Omron G5LA-1-HA-relay

Hi Joseph

Double check the heating element, and also check again the front stat if the pcb is not getting the right reading it will not heat up. when you have checked that the wiring is good and ntc and heater then it might be a fault with the pcb

 

Omron relay fitted on printed circuit board with wiring

Omron relay fitted on printed circuit board with wiring

Old Omron relay fitted on pcb with wiring

Old Omron relay fitted on pcb with wiring

Old Omron relay fitted on pcb soldered pins side up

Old Omron relay fitted on pcb soldered pins side up