Tumble Dryer

hoover Dynamic mega 10k DMCD1013B-80 error code 15

September 14, 2020
Customer Question

Digital lights flashing Displaying error code 15, dryer still working

Paul
Paul Repair Expert

I will try and help with your Hoover DMCD1013B-80 Tumble Dryer problem

Error E15 indicates your washing machine has a corrupted or incorrectly programmed control board. The only way to fix this is to order a new board pre-programmed and replace the faulty one. Do make sure it is programmed for your model, as they also sell the board unprogrammed, and only engineers with the right equipment can program them. I've listed all the errors applicable to your model below for your convenience.

 

ERROR CODE

MOST PROBABLE REASON FOR THE ERROR CODE

E03 

Tank is full of water and has to be emptied

E05 

Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or wiring

E07

Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is occluded because of fluff  presence, the correct ventilation is not allowed. Clean the filter

E08 

Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is clean, check the  wiring

E10 

Missing communication between "Cuore" Electric Module and Display Electric Module and/or Wiring

E11

In the rear part of condenser the temperature is too high. Check that all ventilation ducts are clean, check that ventilation system is working well. Check the condenser, the moto  the fan could be broke/blocked.

E12   

Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air trap is clean

E13 

Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC probe and/or wiring

E14 

Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or wiring

E15   

Main board not programmed. Program the main board

E19

It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off and switch on)

E21   

Heater control relay on the “cuore” electric module is not working. High temperature has been reached - Thermo Fuse worked. Check the Thermo Fuse, and the wiring. Check both the ventilation circuit and ventilation ducts are clean and duct is not obstructed. Replace the “cuore” electric module only in the case that the heater command relay is faulty

E22

Compressor control relay on the “cuore” electric module is not working. Check the compressor and compressor wiring/connections. Replace the “cuore” electric module only in the case that the compressor command relay is faulty.

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances