Tumble Dryer

Hoover DYC 8913 B -80 tumble dryer Not Heating Thermal Fuse blown

December 30, 2020
Customer Question

Sir, Firstly, A Happy New Year and thank you for the excellent videos, which have been so helpful. A pint or two will definitely be on the way after this problem is finally resolved!I now realise our dryer had two problems. Initially I replaced the thermal fuse mounted above the heater (left side) but it has now blown again. Sometimes the dryer failed to start with the buzzing sound which I have learnt from your video is a failed or failing condenser, so yesterday I ordered a replacement (7mf) and another thermal fuse from your eBay shop. I managed to carefully extract the defective condenser with the drum in place.After discussions with my wife I understand that sometimes the dryer stops mid cycle, when hot, with the same buzzing sound, presumably when about to change direction. Error code, possibly E8 and/or flashing display occurred.I have tested everything else I can reach with the exception of a temp sensor at the back in the ducting below the drum. I am reluctant to remove the drum incase I have a problem re-fitting the belt!From the above, do you think it is possible that the replacement thermal fuses blew (after a couple of weeks) due to overheating when the drum failed to reverse and the heaters may have still been active? Your advise will be very much appreciatedkind regardsRobert

Paul
Paul Repair Expert

I will try and help with this problem Hoover 31100391 - DYC 8913B-80 condensor tumble dryer

 

if the motor at any point had stopped this may cause the heater to overheat because the airflow would not be going over the heater, the other reasons why the TOC could fail if people open the door mid-cycle or the tumble dryer is not allowed to complete its program the machine will not go down.  the cool-down period at the end of each program is important also if the filters are blocked or any restriction in airflow this would also cause the heater to get too hot, the TOC is designed to blow when it exceeds 206 degrees or more I have added some useful videos to assist you in any repairs in the future and also an exploded diagram of the machine I have also sent you over a PDF file and I have listed all the error fault codes codes below

 

 

If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.

YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

 

Hoover 31100391 - DYC 8913B-80 condensor tumble dryer spare parts

Hoover DYC 8913 B -80 error codes or fault codes

Match your part for Hoover 31100391 – DYC 8913B-80 condensor tumble dryer and the use reference number in list below and click on the link to your part

Reference Part Number Description
10 41031869 Timer/select. knob
31 40006653 Control panel
48 41019260 R/H side frame
48a 41019261 L/H side frame
49 40004597 Top rear frame
49g 91617795 Trade mark plate
51 40004601 Work top
60 40006227 Hinge
63 40006231 Door glass
76 40004998 Cabinet-assy
77 40004062 Rear panel
79 40002885 Foot
82 40006377 Door panel
88 40005140 Front panel
131a 92470020 Hose clip
151h 41033178 selector 12 settings
152 40006295 Switch assy
153 28375043 Pressure switch
156c 09069857 Capacitor 8 MF
157 41033719 Harness
157 41037150 Harness
161 40005021 Pump
164 91200489 Anti jamming filter radio
171 40005004 Main motor
202 40005712 Drum
205 40006362 Drum shaft assy
218 03210179 Bearing
219 21446068 Bolt
229 24721202 Circlip
230 40004306 Bearing clamp
271 40005393 Door gasket
292 40001012 Drive belt
318 40006367 Electronic control PCB programmed
328c 40006406 Programmed PCB complete
440a 46004464 Scroll seal
442 40004669 Fan
442a 40001069 Rear fan
443 41037151 Thermostat
448 40004314 Heater
448 40006990 Heater
448 40007271 Heater
448 40005010 Heater
461h 41014595 drying probe seal
491c 91200201 Mains cable x UK
494 40006375 Red window
520 40004092 Door coupler
607 40006220 Pin for hinge
631 40006586 Stopper
647 40004812 Water condenser
654 40003802 Thermostat gasket
671 03610428 Washer
690 40006246 Rear sealing felt
690a 40004577 Rear cover seal
696 40003227 Heater support
697 40003226 Heater support disk
706 40007123 Front ring assembly
707 40005584 Filter for carter
727 40004816 Gasket
731a 40006252 Delivery pipe (Water delivery)
731b 40006360 Flow pipe (Water drain)
734 40006402 Container
738 40004817 Gasket
743a 40005160 Cover frame
745 40005233 Kickplate assy
755 40004808 Cover
755a 40004809 Fan insert
756 23715194 Spring
757 40003315 Gasket
763b 40003319 Water rear duct gasket
763d 40005020 Reservoir top cover
764 40004815 Gasket
766 40006253 Water container assy
766b 40004928 Water container front cover
777 40004157 Heater gasket
777a 40005154 Heater cable seal
797 40004610 Beltightening pulley
799 40001026 Belt tighteningb spring
804 40006225 Hinge fixing upper bracke
819 40005449 Drum scowel
822 40006248 Innerdoor assy
826 40004091 Door hook
835 40004307 Drum support wheels
1004 40005153 Flow restrictor
1017 40003258 NTC probe
1023 40004929 Cool air duct assy
1026 40004946 Front felt
1037 40006230 Water filter

full list of spare parts for this model below Hoover 31100391 – DYC8913B-80 condensor tumble dryer

Parts for This Model

Showing compatible parts for model DYC 8913 B -80

Request a part →
Finding compatible parts…