Candy GVS C9DCGB-80 condenser tumble dryer E22 error code the fault is it stops after a few secs
Stops whatever cycle after less than 30secs with E22 all lights flashing alarm. Have followed your videos and have continuity on safety thermostat but I don’t seem to have continuity on the other one, but I don’t seem to have a link cable. Tried continuity by taking off each wire but still nothing. Can’t find this part on spares websites.
I will try and help with this problem Candy GVS C9DCGB-80 condenser tumble dryer
there are three thermostats on this machine two of them are on the heater a 206c cut out thermostat, I am not sure if the one next to this is an NTC sensor or it is a cycling thermostat, then there is one at the front 443 in the diagram. If all of these are in good condition you need to test the heater. it has two sides to it a high and low side you should have an ohms reading on both sides of the element to match the wattage. the other common problem with these tumble dryers are the circuit board relay. you can find out all about these in the videos below I hope this helps you identify the problem with youre tumble dryer
If you want to support the site please mark us to your favourites, also I would be grateful if you would subscribe to our social media channels as this really helps my site and keeps us going.
YouTube. http://www.youtube.com/user/howtorepair
Facebook. https://www.facebook.com/how.to.repair.appliances
And if we really helped you save money you can always click on the Buy Paul a Beer page

Candy GVS C9DCGB-80 condenser tumble dryer spare parts
Candy GVSC9DCGB-80 condenser tumble dryer fault codes and errors
Presently available error codes for the SKYLANDER models range
Cuore NFC electric module
ERROR CODE MOST PROBABLE REASON FOR THE ERROR CODE
E03 Tank is full of water and has to be emptied.
E05 Front NTC sensor is either short circuit or open circuit. Check front NTC sensor and/or
wiring.
E07 Alarm, filter occluded, This error can only appear after the end of a cycle. The filter is
occluded because of fluff presence, the correct ventilation is not allowed. Clean the filter.
E08
Thermo fuse intervention. Replace the thermo fuse and check that ventilation circuit is
clean, check the wiring.
E10 Missing communication between "Cuore" Electric Module and Display Electric Module and/or
Wiring.
E11
In the rear part of condenser the temperature is too high. Check that all ventilation ducts
are clean, check that ventilation system is working well. Check the condenser, the motor,
the fan could be broke/blocked.
E12 Pressure switch doesn’t work. Check the pressure switch and/or wiring. Check that the air
trap is clean.
E13 Compressor NTC Probe is either Short Circuit or Open Circuit. Check the compressor NTC
probe and/or wiring.
E14
Rear NTC Probe is either Short Circuit or Open Circuit. Check the rear NTC probe and/or
wiring.
E15 Main board not programmed. Program the main board.
E19
It is not possible to use NFC tag for any actions until the next POWER ON/OFF. (switch off
and switch on)
E21
Heater control relay on the “cuore” electric module is not working. High temperature has
been reached – Thermo Fuse worked. Check the thermo Fuse, and the wiring. Check that
both the ventilation circuit and ventilation ducts are clean and duct is not obstructed.
Replace the “cuore” electric module only in the case that the heater command relay is
faulty.
E22
On none compressor type this may be heat related
Compressor control relay on the “cuore” electric module is not working. Check the
compressor and compressor wiring/connections. Replace the “cuore” electric module only
in the case that the compressor command relay is faulty