Tumble Dryer

AEG – T56840L Condenser 7kg Tumble Dryer E51 error fault

March 29, 2017

Customer Question

Mark Spolton asks:

Starts ok, runs for 3-4 minutes,then faults,but after a few resets will run through full cycle

Model: T56840L

P

Paul Says:

I will try and help with this problem...

 

if you are getting an intermittent ​error code e51 and you have changed the capacitor on the motor, then there's a good chance that you have a faulty circuit board this is a common fault on the​se​ circuit boards​, the links switch can go faulty you can try inspecting it with a magnifying glass for any hairline cracks, they are not always visible but I have changed a lot of these and it has cleared the error, I have included a video below showing you what to do, and I have also put some of the parts that we sell for your AEG - T56840L Condenser 7kg Tumble Dryer

 

Only attempt this repair if you are sure that this is the problem

Spare parts for your AEG – T56840L Condenser 7kg Tumble Dryer

Parts for This Model

Showing compatible parts for model T56840L

Request a part →
Finding compatible parts…